    Terpenes in Hemp Oil Part #CMQC-080, PRACTICE/INTERNAL PT

    Sample set supplied as a blank hemp oil matrix and a certified spiking solution containing at lease 8 terpenes per study. This PT is suitable for compliance with BCC and Florida as well as other USA states' statutory requirements

     

     Certificate of Analysis

    Terpenes 

    Catalog Number: 

    CMQC-080

    Expiration:

    09/30/2022

    Lot Number:

    H0920

    Solvent:

    Isopropanol

    Manufacture Date:

    08/19/2020

    Hazards:

    Irritant, Flammable

    Analyte

    Study

    Certified

    Acceptance

    Analyte

    CAS

    Purity

    Mean

    Concentration

    Limits

    (mg/g)

    (mg/g)

    (mg/g) 

    alpha-Pinene

    80-56-8

    98.3%

    0.00

    0.00

    ±

    0.00

    0.00

     

    0.00

    Linalool

    78-70-6

    99.8%

    0.571

    0.647

    ±

    0.01

    0.317

     

    0.824

    Myrcene

    123-35-3

    93.0%

    0.425

    0.467

    ±

    0.00

    0.191

     

    0.659

    d-limonene

    5989-27-5

    99.5%

    1.67

    1.48

    ±

    0.01

    1.33

     

    1.92

    Beta-Caryophyllene

    87-44-5

    99.5%

    0.00

    0.00

    ±

    0.00

    0.00

     

    0.00

    alpha-Humulene

    6753-98-6

    96.1%

    1.29

    1.26

    ±

    0.01

    0.504

     

    2.08

    Terpinolene

    586-62-9

    94.0%

    0.00

    0.00

    ±

    0.00

    0.00

     

    0.00

    Ocimene (mix of isomers)

    13877-91-3

    94.6%

    0.00

    0.00

    ±

    0.00

    0.00

     

    0.00

    (-)-Caryophyllene

    1139-30-6

    99.5%

    0.321

    0.322

    ±

    0.00

    0.092

     

    0.055

    (-)-alpha-bisabolol

    23089-26-1

    93.0%

    0.00

    0.00

    ±

    0.00

    0.00

     

    0.00

    Camphene

    79-92-5

    96.8%

    0.00

    0.00

    ±

    0.00

    0.00

     

    0.00

    3-Carene

    13466-78-9

    98.5%

    1.87

    1.93

    ±

    0.02

    1.14

     

    2.60

    Geraniol

    106-24-1

    99.1%

    0.00

    0.00

    ±

    0.00

    0.00

     

    0.00

    p-cymene

    99-87-6

    100%

    0.00

    0.00

    ±

    0.00

    0.00

     

    0.00

    (-)-Isopulegol

    89-79-2

    100%

    0.00

    0.00

    ±

    0.00

    0.00

     

    0.00

    Nerolidol (mix of isomers)

    7212-44-4

    99.1%

    1.46

    1.45

    ±

    0.01

    0.146

     

    3.47

    gamma-Terpinene

    99-85-4

    98.7%

    0.000

    0.00

    ±

    0.00

    0.00

     

    0.00

    Eucalyptol

    470-82-6

    99.8%

    0.541

    0.588

    ±

    0.01

    0.054

     

    1.22

    (-)-beta-Pinene

    18172-67-3

    99.6%

    0.00

    0.00

    ±

    0.00

    0.00

     

    0.00

    alpha-Terpinene

    99-86-5

    98.4%

    0.00

    0.00

    ±

    0.00

    0.00

     

    0.00

    Packaging, Storage, Instructions For Use

    This CRM is packaged in an amber vial and must be stored at 2°C to 8°C. To use this CRM, allow it to reach room temperature. Add 1mL of spike to 1g of matrix as an amount of sample. Extract and analyze by your approved method. No dry weight correction is required.

    Traceability Information

    Analyte Source Materials: The highest purity analyte source materials are used in the manufacture of this CRM. The actual purity is referenced above.

    Method: This CRM was verified

    Volumetrically/Gravimetrically and Analytically

     

    Catalog Number: 

    CMQC-080 

    Lot Number: 

    H0920 

    Glassware: All glassware used in the manufacture of our standards is Class A. An in-house standard operating procedure is used to verify all glassware prior to it being placed into service. Volumetric pipetors are calibrated every four months by an ISO 17025 accredited calibration laboratory.

    Intended Uses 

    â–ª Calibration of analytical instruments 

    â–ª Validation of analytical methods 

    â–ª Preparation of working level reference materials, i.e. "check standards" 

    â–ª Detection limit studies 

    Homogeneity 

    This CRM was thoroughly mixed in production and is guaranteed homogenous. 

    ________________________________________________ 

    Mark Hammersla, President