Huber CS 100-H

SKU:
VDH1100690
  • Description

    Huber CS 100-H

    Chiller with air-cooled refrigerating unit and circulation pump (stainless steel). Housing, atmospheric open tank and copper soldered evaporator made of stainless steel. With digital level indicator. Condenser in air-cooled design, performanceoptimized by a built-in high-efficiency fan motor. Powerful feed pump with integrated overtemperature protection. The flow rate can be adjusted via the manual bypass valve on the backside of the chiller. Control unit B400 / RB400: Capacitive operating interface with OLED display and multi-coloured status notification for instant identification of the current operating status. Choice of eight different system languages (DE, EN, ES, FR, IT, PT, RU, TR). Separate operating option for the feed pump and the cooling unit with convenient adjustment of the desired setpoint. Operating of the system can be evaluated on a PC or notebook via an integrated RS232 interface.

    Technical data according to DIN 12876 Operating temperature range -20...+85 °C Temperature stability at -10°C ±1.5 K temperature set point / display colour LED Touchscreen Internal temperature sensor Pt100 Interface digital RS232 Safety classification Class I / NFL Cooling power at +15°C 18 kW at +10°C 10 kW at ±0°C 9,5 kW at -10°C 7,5 kW at -20°C 4,5 kW Heating Power 5.5 kW Refrigeration machine air-cooled, CFC- and HCFCfree Refrigerant R449A Refrigerant quantity 4,5 kg Gas warning sensor without Pressure pump max. delivery 83 l/min max. delivery pressure 3,7 bar Pump connection G 3/4” male Bath volume min. 160 l Bath volume max. 175 l sound pressure level +/- 4 dB(A) 70 dB(A) Overall dimensions WxDxH ** 800x850x1665 mm Order-No.: VDH4100106 Net weight 340 kg Power supply requirement 208V 3~ or 460V 3~ 60Hz max. current 35 A or 16 A Fuse on power network side 3x 35 A or 3x 20A Degree of Protection IP20 max. ambient temperature +32 °C min. ambient temperature +5 °C

    Technical details and dimensions are subject to change. No liability is accepted for errors or omissions. Illustrations can deviate from the original. Accessories and periphery: 2pcs Hose nozzles ∅20mm*, bath cover*, overpressure. Bypass valve*, Bypass valve*, drain valve, thermofluid, RS232 cable * standard accessories Output data valid for: Room temperature 20°C. If the ambient temperature rises, the cooling capacity may drop. In accordance with EN60034-1 the following voltage and frequency tolerances are valid: Voltage + / - 5% with a simultaneous frequency tolerance of + / - 2% Example: 5% voltage and +2% frequency -> not allowed! - 5% voltage and - 2% frequency -> allowed Information to Electromagnetic compatibility: Classification (disturbance) to EN55011: Class A, Group 1 Recommended thermofluid: Water - Monoethylene Glycol 50:50 Standard delivery conditions - Power cable configuration: 1. Single-phase devices (115V) -> with cable and plug 2. Two-phase devices (208V) -> with cable, without plug 3. Three-phase devices (208V/460V) with current consumption less than 63A -> with cable, without plug 4. Three-phase devices (208V/460V) with current consumption greater than 63A -> with cable, without plug