Description
IKA Rotavisc SBS hi-vi II Complete
The SBS (Steel Ball Bearing, Suspended) rotational viscometers extend a large part of the application spectrum of our IKA ROTAVISC device family.
Instead of a jewel bearing, these devices are equipped with a special ball bearing technology.
They are characterized by their high robustness. Predestined for applications with very high sample throughput, frequent spindle changes, operation in harsher environments, or even frequently changeing device locations.
Whether simple or demanding viscosity measurements - with ROTAVISC you get fast and accurate results.
Easy to use
Intuitive menu navigation awaits you via the generous 4.3" TFT display. A digital leveling also supports the correct setting of the starting condition. Recurring tasks are facilitated by the simple ramp function.
Highest measurement accuracy
The accuracy of the ROTAVISC rotary viscometers for Newtonian and non-Newtonian liquids is +/- 1 % of the measuring range. The reproducibility is +/- 0.2%.
Infinitely variable speed
With ROTAVISC you have a viscometer in which you can adjust the speed stepless, but also specify programs or individual speed levels.
IKA Rotavisc SBS hi-vi II Complete
Viskosität-Measuring range: 800 - 320.000.000 mPas
Scope of delivery
- ROTAVISC SBS hi-vi II control
- ROTASTAND
- SP set-2
- PT 100.8
- Guard rail
Technical Data
Viscosity Measuring Range | 320000000 mPas |
Viscosity Accuracy (FSR) | 1 % |
Viscosity Repeatibility (FSR) | 0.2 % |
Spring torque | 5.7496 mNm |
Guard rail | me-vi |
Measuring spindle series | SP set-2 |
Motor rating output | 4.8 W |
Overload protection | yes |
Direction of rotation | right |
Display | TFT |
Speed display | TFT |
Speed range | 0.01 - 200 rpm |
Setting accuracy speed | ±0.01 rpm |
Speed control | TFT |
Torque display | yes |
Torque measurement | yes |
Timer | yes |
Timer display | TFT |
Time setting range | 0.017 - 6000 min |
Temperature measurement resolution | 0.1 K |
Working temperature display | TFT |
Connection for ext. temperature sensor | PT 100 |
Graph function | yes |
Operating mode | timer and continuous operation |
Calibration option | yes |
Touch function | yes |
Pemitted density | 9999 kg/dm3 |
Working temperature | -100 - 300 °C |
Fastening on stand | extension arm |
Support rod diameter (with integrated fastening on stand) | 16 mm |
Telescope stand stroke | 200 mm |
Plug-in coupling (Ø) | 12 mm |
Basic container volume | 600 ml |
Stand | Rotastand |
Stroke max. | 61 mm |
Diameter | 16 mm |
Dynamic load | 5 kg |
Dimensions (W x H x D) | 351 x 629 x 372 mm |
Weight | 7.1 kg |
Permissible ambient temperature | 5 - 40 °C |
Permissible relative humidity | 80 % |
Protection class according to DIN EN 60529 | IP 40 |
RS 232 interface | yes |
USB interface | yes |
Voltage | 100 - 240 V |
Frequency | 50/60 Hz |
Power input | 24 W |
Power input standby | 0.06 W |
DC Voltage | 24 V= |
Current consumption | 1000 mA |