MD 100 Phosphate, with powder reagents

SKU:
276045
  • $545.00
  • Description

    MD 100 Phosphate, with powder reagents

    The MD 100 has several key features that make it a favorite among users.

    • Waterproof Design
      The IP 68 design of this instrument ensures that the MD 100 remains water tight for up to 1 hour at 0.1 meter. Don't worry about dropping the instrument into a body of water - it floats!
    • Accurate, Reproducible Results
      The optical system of the MD 100 utilizes LEDs and interference filters which quickly gives you results that you can be confident in.
    • User Calibration Mode
      A one-point calibration is possible. Additionally, all MD 100 instruments have the ability to display readings directly in ABS or %T units.
    • One-time-Zero Function
      Don't waste time waiting for your instrument to Zero after each test. When testing a new sample, zero the instrument once and all subsequent tests of that sample do not require you to re-zero the instrument.
    • Automatic Data Storage with Transfer Capabilities
      The MD 100 automatically stores the last 16 readings with time and date stamp. These results can be transferred to a spreadsheet using the IRiM accessory.
    • Ergonomic Design
      Whether you're using the MD 100 out in the field or in the lab, the design of the instrument makes it easy to handle and view the display. If you're using the instrument in the lab, the rubber feet on the bottom of the housing eliminates the need for two hand operation or to chase your instrument around the workbench.
    • Factory Programmed
      All MD 100 instruments are supplied ready to use with up to 14 calibration curves. All you need to do is select the test you need, prepare your sample and test!
    • Scroll Driven Menu System
      The simple interface allows you to quickly reach the test you need. When the instrument is turned on, it will automatically display the last test used.
    • 2-Year Manufacturer's Warranty

    Optics LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used. Wavelength specifications of interference filters:
    430 nm Δλ = 5 nm
    530 nm Δλ = 5 nm
    560 nm Δλ = 5 nm
    580 nm Δλ = 5 nm
    610 nm Δλ = 6 nm
    660 nm Δλ = 5 nm
    Wavelength Accuracy ± 1
    Photometric Range -2500 - 2500 mAbs
    Suitable Vials Round Cuvettes 24 mm
    Display backlit LCD (on keypress)
    Interfaces Infrared
    Operation Foil keypad
    Calibration factory calibration and user calibration. Reset to factory calibration possible
    Internal Storage internal ring memory for 16 data sets
    Power Supply 4 micro batteries (AAA)
    Battery Life Time approx. 17 hours
    Clock Real Time Clock and Date
    Portability Portable
    Compliance CE
    Dimensions

    6.1 x 2.95 x 1.38"

    Test parameter  Measuring Range  Method No.  Chemical Method
    Phosphate LR T 0.02 - 1.3 mg/L P M320 Phosphomolybdenum Blue
    Phosphate PP 0.02 - 0.8 mg/L P M323 Phosphomolybdenum Blue