PLEASE NOTE: We will be closed Monday 11.11.2024 in observance of Veterans' Day.

Huber Unistat 510 with Pilot ONE

SKU:
1070.0004.01
  • $57,750.00
  • Description

    Huber Unistat 510 with Pilot ONE
    The Unistat range inspires with unique thermodynamic properties and a range of functions to meet the highest demands. Unistat technology guarantees precise, reproducible temperature control results, the shortest possible heating and cooling times and large temperature ranges without the need for fluid change. All Unistats are fitted with the innovative Pilot ONE controller with a 5.7“ touchscreen colour display and easy menu navigation. All important parameters can be seen at a glance and temperature curves are displayed in graphic real time. Unistats are equipped with the most up-to-date pump technology for optimal heat transfer. The pump self regulates to ensure the best possible circulation and flow and delicate glass reactors are protected from breakage by the pumps soft start-up feature. Unistat technology impresses as a result of economic operation with reduced operating costs and efficient energy management. Because Unistats are hydraulically sealed, the service life of the temperature control fluid is dramatically increased by preventing oil loss through vapours and oxidation, further saving resources. Unistats are fitted with extensive safety equipment and are therefore suitable for unsupervised continuous operation. Relevant operating conditions are constantly monitored and the system is switched off if necessary or with the process safety feature the emergency cooling circuit is activated.
     The new multi-touch controller Pilot ONE offers a brilliant 5.7" touchscreen with graphic functions and a comfortable navigation menu. All important operating parameters and temperature values are neatly displayed on the touchscreen. Thanks to the new favourites menu, the one-click operation and the integrated technical glossary the operation is very easy, just like on a smartphone. Integrated USB and Ethernet ports allows connection to a PC or network, e.g. for remote control or data transmission. The E-grade Explore turns a Unistat into a development tool for process and chemical engineering.
    Precise and reproducible temperature control results
    Fastest heating and cooling rates
    Wide temperature ranges with no fluid change
    Pilot ONE controller with 5.7“ touchscreen and comfortable menu navigation
    Adaptive temperature control, self-optimising
    Efficient circulation pump
    2 x USB (Host and Device), Ethernet and RS232 interfaces
    Efficient operation saves working time and operating costs
    Proven functionality for the process industry
    E-grade "Professional" included

     
    General information & temperature controller 
    Temperature range  -50...250 °C
    Temperature stability ±0.01 °C
    Temperature control TAC, self-optimizing (True Adaptive Control)
    Display resolution  0.01 °C
    Alarm message  optical, acoustical
    Controller Pilot ONE (E-grade "Professional") 
    Safety class  III / FL
    Protection class  IP20
    Dimensions (W x D x H) 560 x 754 x 1457 mm | 22.05 x 29.68 x 57.36 inches
    Weight 233 kg | 513.76 pounds
    Heating / cooling capacity 
    Heating capacity  9 kW
    Cooling capacity
    250 200 100 0 -20 -40 -50  °C
    5,3 5,3 5,3 5,3 2,8 0,9 0,25  kW
    Cooling machine air-cooled
    Refrigerant (ASHRAE, GHS) R452A (A1, H280) (2,8 kg)
    Circulation pump  
    Pressure pump max.  112 lpm ; 1.5 bar | 29.59 gpm ; 21.75 psi
    Pump connection  M30x1,5 AG male
    Permissible viscosity  50 mm²/s
    Pump speed adjustable Yes
    Connections 
    Pt100 connection  Pt100
    Analogue input  via optional Com.G@te
    Analogue output  via optional Com.G@te
    Digital interface  RS232, Ethernet, USB Device, USB Host
    Operating data
    Permissible ambient temp. 5...40 °C
    Filling volume min.  4.1 Liters | 1.08 gal
    Volume of expansion 5.5 Liters | 1.45 gal
    Power supply 460V 3~ 60Hz
    Current max. 16 A
    Miscellaneous
    Please take further technical information as well as information about the scope of delivery, accessories and peripheral devices from the PDF data sheet. In cases of doubt the details given in there apply. If nothing to the contrary is quoted then the performance data referred is at an ambient temperature of 20°C.

    Please observe the notes on installation and/or the space requirements of our products.

    The following voltage and frequency tolerances apply based on EN60034-1:
    Voltage +/- 5% for a frequency tolerance at the same time of +/- 2%

    Examples to illustrate this: Not permissible, for example. is -5% on the voltage and +2% on the frequency. Permissible, on the other hand, are tolerances of -5% on the voltage and -2% on the frequency.

    This equipment is compliant to US-SNAP and all applicable EU laws. The US-SNAP end-use for this equipment is the industrial process refrigeration. Certification by a Notified Body upon request.

    We reserve the right to make technical changes and correct errors. Illustrations can deviate from the original.