Ai RapidChill 20 CF Ultra-Low Upright ULT Freezer UL 110V

SKU:
G20h
  • Ai RapidChill 20 CF Ultra-Low Upright ULT Freezer UL 110V
  • Ai RapidChill 20 CF Ultra-Low Upright ULT Freezer UL 110V
  • Ai RapidChill 20 CF Ultra-Low Upright ULT Freezer UL 110V
  • Ai RapidChill 20 CF Ultra-Low Upright ULT Freezer UL 110V
  • Ai RapidChill 20 CF Ultra-Low Upright ULT Freezer UL 110V
  • Ai RapidChill 20 CF Ultra-Low Upright ULT Freezer UL 110V
  • Description

    Ai RapidChill 20 CF -86°C Ultra-Low Upright ULT Freezer UL 110V

    The Ai RapidChill series -86C ultra low temperature freezers is designed for fast cooling, ultra-low power consumption, very low noise, and ease of maintenance. All RapidChill ultra-low freezers are UL certified.

    Features

    • CDC and VFC compliant, great for storage of vaccines, DNA, RNA, virus samples, organs, and serum
    • State-of-the-art Vacuum Insulated Panel (VIP, Micro-Cellular Polyurethane) insulated
    • Safe, environmentally friendly, energy efficient, and easy-to-acquire HC refrigeration system
    • Remote alarm, RS-485, and optional 4-20mA transmitter
    • Door lock, high or low temperature alarms, power failure alarm, door open alarm, filter clogging alarm, password protection, tons of security features to protect you, your products, and the unit
    • Digital temperature display with microprocessor-based temperature controller
    • Dual silicon sealing gaskets for ultra airtight operation
    • 48-hour battery backup for controller and alarm
    • Extremely quiet and reliable
    • Compliant to UL 61010-1, CSA C22.2 and Energy Star standards

    Important!

    • Do not plug in your unit. Leave your Ai refrigerator or freezer for 24 hours before turning the unit on for the first time.
    • This unit is NOT designed to be used on a mobile platform.
     Model  G20h
     Electrical requirements  110V (±10%) 60Hz 1-Phase 1000 watts
     Power consumption  8.5 kW/day, Energy Star certified
     Performance  Temperature range: -40°C to -86°C
     Time from ambient to -86°C: 5.5 hours
     Uniformity: ±4°C
     Time from -86°C to -50°C with door close (ambient 25°C): 4.5 hours
     1 min door open recovery time (ambient 25°C, running temp -75°C): 40 mins
     Controller  - Style: microcomputer controlled with analog display
     - Range -40°C to -86°C
     - Step: 1°C
     - Thermo sensor: PT100
     - Displays: internal temperature, ambient temperature, input voltage, error code
     - Indicators: high/low temperature/battery alarms, sensor failure, power failure,
    condenser failure, door open, high ambient temperature, working
    condition
     Compressor  Make: SECOP (formerly known as Danfoss), Germany
     Style: direct cooling
     Power: 115V 60Hz 1-PHASE, 0.54HP x 2
     Number of compressors: two
     HC refrigerants: R290 (stage 1), R170 (stage 2)
     Chamber  Dimensions: 24.4 x 28.2 x 51.6" (WxDxH)
     Material: powder coated steel
     Capacity: 20.4 Cu Ft
     Insulation: VIP (Vacuum Insulated Panel)
     Shelf  Come with unit: 3 (4 compartments), fully adjustable
     Dimensions: 23.8 x 26.7" (WxD)
     Max. capacity: 175 Lbs
     Material: 304 stainless steel
     Door and gasket  Inner door: four, each with one sealing gasket
     External door: one, with four sealing gaskets, lock-able
     Communication  Standard: RS-485, USB (stores 15 years of data for compliance purpose)
     Optional: 4-20mA transmitter
     Access port  Two
     Noise level  50 dBA
     Working environment  - Temperature: 10°C to 32°C (humidity <57% Rh required at 32°C)
     - Humidity: <80% Rh
     - Altitude: < 2000 m / 6561 Ft
     - Stable, well-ventilated platform with no excessive dust
     - Keep freezer at least 12 inches from any walls or ceiling
     - Use dedicated power, do not share outlet
     - Extension power cable should be less than 10 feet is required
     - Freezer and power outlet should be grounded properly
     - Avoid direct sunlight, water spill and do NOT use freezer outdoor
     - Clean condenser fins and remove frost inside chamber at least once a month
     - Important! Do not plug in your unit. Leave your Ai refrigerator or freezer for
    24 hours before turning the unit on for the first time.
     Battery backup system  48 hours (for controller display and alarms only)
     Unit/shipping weight & dimensions   660 Lbs / 730 Lbs
     36 x 38.5 x 77" / 40 x 42 x 82" (WxDxH)
     Safety  Compressor over-temp protection
     Ambient over-temp protection
     Compressor power surge delay protection
     Password protection
     Sensor failure protection
     Over-temperature and low-temperature protection
     Power failure protection
     Low battery, door open, condenser clogging, system failure alarms
     External door with lock
     Ground protection
     Compliance  UL 61010-1
     CSA C22.2
     Energy Star
     Warranty  2-year full service, 3-year parts, 5-year compressor